ses-led-control

Control the Identify (locate) and Fault LEDs of disk slots in enclosures that speak SES (SCSI Enclosure Services) - e.g. Supermicro / LSI expander backplanes attached to an HBA in IT mode. Built for Linux in general, with TrueNAS SCALE as the primary use case.

TrueNAS SCALE ships sg_ses but has no built-in way to drive enclosure locate/fault LEDs - this fills that gap with the tooling already on the system.

shellcheck License: MIT

It lists every slot of every SES enclosure (including empty ones), maps the installed disk to its slot via the SAS address, shows the slot status and the IDENT/FAULT LED state, and lets you toggle those LEDs - interactively or from a one-shot command.

#   ENCL:SLOT   STATUS       DEV      SERIAL             MODEL                SIZE     FW       IDENT  FAULT
----------------------------------------------------------------------------------------------------------------
0   sg3:0       populated    sda      WDC-SN-0001        WD40EFRX             3.6T     82.0     off    off
1   sg3:7       populated    sdb      ZAB1234            ST8000               7.3T     SN02     off    ON
2   sg5:2       empty        -        -                  -                    -        -        ON     off

number = toggle IDENT | f<n> = toggle FAULT | x = all LEDs off | r = reload | q = quit
>

What it does

  • Enumerates SES enclosures with lsscsi -g.
  • Maps disks to slots by SAS address, using the enclosure Additional Element Status (aes) page and each disk's sas_address in sysfs.
  • Reads slot status and LED state from the Enclosure Status (es) page.
  • Switches LEDs with sg_ses --index=<type>,<idx> --set|--clear=ident|fault.
  • Handles both the Array device slot and Device slot element types automatically.

It does not write to disks and performs no destructive action beyond changing an LED. LED control depends entirely on the backplane's SES support - if the hardware can't do it, this tool can't make it.

Requirements

  • root to switch LEDs (list, --help, --version run unprivileged).
  • sg3-utils - provides sg_ses
  • util-linux - provides lsblk
  • lsscsi
  • awk

TrueNAS SCALE ships all of these out of the box - nothing to install (apt is locked down there anyway).

On plain Debian/Ubuntu:

sudo apt-get install -y sg3-utils util-linux lsscsi

Run

It's a single self-contained script - no install, no clone. Download just the script into any folder and run it with bash. This is also the way to use it on TrueNAS SCALE, where /usr (and /usr/local/bin) is mounted read-only:

curl -fsSLO https://raw.githubusercontent.com/nmuellerdo/ses-led-control/main/bin/ses-led-control
sudo bash ses-led-control

This starts the interactive menu. Re-run the same curl any time to update to the latest version.

Usage

Examples below call ses-led-control for brevity. If you downloaded the script, run it with bash ses-led-control ... from that folder (prefix sudo to switch LEDs).

Interactive

sudo bash ses-led-control

Then, at the prompt:

Input Action
<n> toggle the IDENT LED of row n
f<n> toggle the FAULT LED of row n
x clear all IDENT and FAULT LEDs
r reload the table
q quit

Non-interactive (CLI)

ses-led-control list
sudo ses-led-control ident on <target>
sudo ses-led-control ident off <target>
sudo ses-led-control fault on <target>
sudo ses-led-control fault off <target>
sudo ses-led-control off-all
ses-led-control --version
ses-led-control --help

list prints the table and exits (no root needed); ident/fault switch the respective LED; off-all clears every IDENT and FAULT LED.

--dry-run prints the sg_ses commands instead of running them, and works without root - handy for scripts and for confirming which slot you're about to light up:

$ ses-led-control --dry-run fault on sg3:7
sg_ses --index=arr,7 --set=fault /dev/sg3

Targets

<target> can be any of:

Form Example Meaning
/dev/sdX /dev/sdf a block device
sdX sdf a block device (short form)
<serial> ZAB1234 a disk serial (as shown in the table)
sgN:slot sg3:7 enclosure device + slot index

Example - locate a disk by serial, then mark another as faulty:

sudo ses-led-control ident on ZAB1234
sudo ses-led-control fault on /dev/sdf

IDENT vs. FAULT

  • IDENT (a.k.a. locate / identify) is the LED you turn on yourself to physically find a drive - "which bay is sdf?". It usually shows as blue or a steady/blinking white LED, depending on the backplane.
  • FAULT marks a slot as failed. Some setups drive it automatically (e.g. a ZFS failure); you can also set it by hand to flag a disk for replacement. It is typically red/amber.

Both are just SES element bits - this tool sets or clears them. What color/blink pattern the backplane shows is up to the hardware.

Safety

  • This switches LEDs on real hardware and needs root to do so.
  • It never writes to disks; the only state it changes is LED state.
  • --dry-run lets you preview the exact sg_ses invocation first.
  • off-all is a safe reset if you lose track of what's lit.

Troubleshooting

Empty table / "no slots read"

Reading the enclosure status pages usually requires root. Run list as root:

sudo ses-led-control list

"No SES enclosure found"

lsscsi -g reports no enclosure. Your backplane may not expose SES, or the HBA may be in RAID (not IT/HBA) mode. Confirm with:

lsscsi -g | grep -i enclosu

The sg_ses -p es parser and version differences

The slot state is parsed from the human-readable output of sg_ses -p es. The field names in that output can vary slightly between sg3-utils versions, so the parser keys on these tokens (in bin/ses-led-control, function build_slots):

  • element types Element type: Array device slot / Device slot
  • per-slot markers Overall descriptor: and Element <n> descriptor:
  • the status: field
  • Ident=<0|1>
  • Fault reqstd=<0|1>

A typical descriptor looks like this:

    Element 7 descriptor:
      Predicted failure=0, Disabled=0, Swap=0, status: OK
      OK=1, Reserved device=0, Hot spare=0, Cons check=0
      ...
      Enclosure bypassed B=0, Ready to insert=0, RMV=0, Ident=0
      Report=0, App client bypassed B=0, Fault sensed=0, Fault reqstd=0

If your sg_ses labels these differently, the table columns for STATUS / IDENT / FAULT may come up blank or wrong. To adapt, run:

sudo sg_ses -p es /dev/sgN

and adjust the matching patterns in build_slots (the /Ident=/, /Fault reqstd=/ and status: rules) to match your output. If you hit this, please open an issue and paste the output of sg_ses -p es /dev/sgN - that's exactly what's needed to widen the parser.

Development

Run the linter and the offline self-test (no hardware needed):

shellcheck -x --shell=bash bin/ses-led-control tests/*.sh
bash tests/dry-run-parity.sh

The self-test sources the tool, injects a synthetic enclosure state, and asserts that target resolution and the --dry-run command output are correct. Both run in CI on every push.

Uninstall

Nothing is installed system-wide - just delete the script:

rm -f ses-led-control

Acknowledgements

  • Developed and tested on TrueNAS SCALE against a Supermicro SC846P chassis with an LSI SAS3x36 expander backplane.
  • Written with the help of Claude (Anthropic), using Claude Code.

License

MIT © 2026 Niclas Müller

About

Control the Identify/Fault LEDs of SES enclosure disk slots via sg_ses - single bash script, made for TrueNAS SCALE